Close Loop Type Current Sensor
A Closed Loop type current sensor operates on the principle of magnetic compensation. It measures DC, AC or pulse currents and their combinations. Galvanic isolation techniques is used to separate the primary and secondary circuits.
Close Loop Type Current Sensor
A Closed Loop type current sensor operates on the principle of magnetic compensation. It measures DC, AC or pulse currents and their combinations. Galvanic isolation techniques is used to separate the primary and secondary circuits.
N50H
The current transducer series NxxH operates on the principle of magnetic compensation.
N1002H
The current transducer series NxxH operates on the principle of magnetic compensation.
N125P
The current transducer series NxxH operates on the principle of magnetic compensation.
N2002P
The current transducer series NxxH operates on the principle of magnetic compensation.
Y06-500A
The current transducer series Y06-500A operates on the principle of magnetic compensation.
Y06-1000
The current transducer series Y06-1000A operates on the principle of magnetic compensation.
Serie | N25 | N50H | N100H | N125P | N2002P | Y06-500 | Y06-1000 | |
Mounting type |
PCB * |
* |
* |
* |
* |
* |
|
|
Terminal plug |
* |
* |
||||||
Current measuring range |
I PN *1 |
±25A |
±50A |
±100A |
±125A |
±200A |
±500A |
±1,000A |
Max. |
±50A |
±90A |
±180A |
±200A |
±300A |
±800A |
±2,000A |
|
Step response to 90% of I PN *1 |
<0.5μs |
<0.5μs |
<0.5μs |
<1μs |
<1μs |
<1μs |
<1μs |
|
Supply voltage ±12...15VDC |
±15...24VDC |
|||||||
Output Current ratio output(mA) 2.5V±0.625 |
||||||||
Current conversion ratio |
1-2-3-4:1,000 |
1:1,000 |
1:2,000 |
1:1,000 |
1:2,000 |
1:5,000 |
||
Non-linearity error |
<±0.2%/I PN |
<±0.1%/I PN |
<±0.1%/I PN |
<±0.15%/I PN |
<±0.15%/I PN |
<±0.1%/I PN |
<±0.15%/I PN |
|
Ambient operating temperature |
Min. -40°C |
-40°C |
-40°C |
|||||
Max. 85°C |
70°C |
85°C |
||||||
Energy Management |
* |
* |
* |
* |
* |
* |
* |
|
Drive Motion |
* |
* |
* |
* |
* |
* |
* |
|
Domestic Appliances |
* |
* |
* |
* |
* |
* |
||
Industrial Automation |
* |
* |
* |
* |
* |
* |
* |
*1 IPN = Current nominal measuring range